Phoenix International delivers high performance, high capacity and fault-tolerant RAID and Disk Array Subsystems that are configured to meet the user’s specific data storage requirements. These systems provide state of the art features such as cableless, midplane-based high density chassis, enclosed and isolated drive canisters and redundant, hot-swap components.Our most robust system, the RPC24, was designed to be compliant with military and industrial specifications such as MIL-STD-901D, MIL-STD-810G, MIL-STD-461F and NEBS level 3.
12-Bay Rugged RAID System
Description
Additional Details
Phoenix International’s RPC12 is a high-performance Fibre/SAS/iSCSI Host Channel, 6Gb SAS Solid State/Hard Disk Drive RAID Storage Array that delivers a level of operational environmental capability not previously available in COTS Data Storage Systems. The Storage Area Network (SAN) ready RPC12 features a 12 Hard Disk Drive array housed in a rugged 3U (5.25″) panel height enclosure providing 16Gb FC, 12Gb SAS, or 10GigE iSCSI host interfaces to high-performance 6Gb SAS HDDs and SSDs.
The RPC12 was designed to be compliant with military and industrial specifications such as MIL-STD-901D, MIL-STD-810G, MIL-STD-461E and NEBS level 3. The unique design of the RPC12’s rugged, cableless, passive mid-plane-based, high-density 3U chassis provides an increased environmental operational envelope (0° to +70°C, 45,000 ft altitude with SSDs), redundant, hot-swap components and massive storage capacity while assuring the highest level of data availability.
Features
- 3U Ruggedized Quad Port RAID System
- Single Active or Dual Active, Failover/Failback Controller
- Two/Four 16Gb/sec Fibre Channel, 12Gb SAS, or 10GigE iSCSI ports
- Sustained Read/Write Data Rates to 3300MB/s and 2400MB/s respectively
- Battery Free Cache Backup
- Enclosed and Electrically Isolated Hot-Swap Drive Canisters
- Operational Altitude to 45,000 ft
- Operational Temperature 0° to 70°C
- 40 to 440Hz, 90/240 VAC Input Operation
- Slide Mountable
- Windows, Linux and Unix Support (Cluster Certified)
- Redundant, Hot-Swap Components/FRUs
- Management GUI and Failover Software
- Very Cool Operation – Less than 6.7°C Max. Temp. Rise
- Supports 2.5” & 3.5” Devices
- Made in USA
Supported Interfaces
- 16Gb/sec Fibre Channel
- 12Gb/sec Serial Attached SCSI (SAS)
- 10GigE iSCSI
Configuration
- Host OS Independent
- Single or Dual Hardware RAID
- Up to 12 Enclosed SAS Hot-swap Disk Drives
- 2 Redundant Hot-swap 650W Power Supplies
- 4 Redundant 80 CFM Hot-swap Cooling Fans
Raid Operation
RAID Levels | 0, 1, 5, 6, 10, 50, 60, NRAID and J-BOD |
---|---|
Cache | Up to 4GB per controller |
Cache Backup | Yes, battery free |
Virtual disks per system | 32 |
Particions per virtual disk | 256 |
Management
Consoles | WEB GUI, CLI, Array Administrator |
---|---|
Interface Types | Mini DB9 RS232, 10/100 Ethernet |
Protocol Support | SNMP, SSL, SSH, SMTP |
Management Software | RAIDar, SMC |
Electrical
AC Input Power | 90 to 264 VAC, 40 to 440HZ |
---|
Interoperability
Compatible with FC-SW-2 compliant switches Management interoperability with leading SANmanagement applications
Physical
Height | 5.15”(13cm) – 3U |
---|---|
Weight | 47 lbs |
Width | 17.00” body (slide mountable) |
Depth | 20.77”(52.8cm) Rack mount flange to chassis rear panel |
Environmental (Standard Range)
Shock & Vibration
Operating Shock | 20g @ 11 msec |
---|---|
Nonoperating Shock | 300g @ 2 msec |
Operating Vibration | 3g @ 10 to 500Hz |
Nonoperating Vibration | 7g @ 22 to 500Hz |
Temperature/Humidity
- 5 to 55°C (operational)
- -40 to 85°C (non-operational)
- 5% to 95% non-condensing
Altitude
- 0 to 10,000 ft (operational)
- 0 to 40,000 ft (non-operational)
ENVIRONMENTAL (Extended Range with Solid State Disks)
Temperature Humidity
- 0 to 70°C (operational)
- -40 to 85°C (non-operational)
- 5% to 95% non-condensing
Altitude
- 0 to 45,000 ft (operational, non-operational)
EMC Complicance
- FCC 15.109:2006 Class A (Radiated Emissions)
- FCC 15.107:2006 Class A (Conducted Emissions)
- MIL-STD-461: RS103, RE102, CE102, CS114